add COMPANY_ID_ for supported manufacturers

This commit is contained in:
Matthias Ringwald 2016-01-05 16:22:13 +01:00
parent 30ea30c420
commit c6d1dbed3c
2 changed files with 13 additions and 6 deletions

View File

@ -900,5 +900,12 @@ typedef enum {
// also, invalid parameters
// and reserved
// Company identifiers / manufacturers
#define COMPANY_ID_CAMBRIDGE_SILICON_RADIO 0x000A
#define COMPANY_ID_TEXAS_INSTRUMENTS_INC 0x000D
#define COMPANY_ID_BROADCOM_CORPORATION 0x000F
#define COMPANY_ID_ST_MICROELECTRONICS 0x0030
#define COMPANY_ID_EM_MICROELECTRONICS_MARIN 0x005A
#endif

View File

@ -844,7 +844,7 @@ static uint32_t hci_transport_uart_get_main_baud_rate(void){
if (!hci_stack->config) return 0;
uint32_t baud_rate = ((hci_uart_config_t *)hci_stack->config)->baudrate_main;
// Limit baud rate for Broadcom chipsets to 3 mbps
if (hci_stack->manufacturer == 0x000f && baud_rate > 3000000){
if (hci_stack->manufacturer == COMPANY_ID_BROADCOM_CORPORATION && baud_rate > 3000000){
baud_rate = 3000000;
}
return baud_rate;
@ -923,7 +923,7 @@ static void hci_initializing_run(void){
hci_send_cmd_packet(hci_stack->hci_packet_buffer, 3 + hci_stack->hci_packet_buffer[2]);
// STLC25000D: baudrate change happens within 0.5 s after command was send,
// use timer to update baud rate after 100 ms (knowing exactly, when command was sent is non-trivial)
if (hci_stack->manufacturer == 0x0030){
if (hci_stack->manufacturer == COMPANY_ID_ST_MICROELECTRONICS){
run_loop_set_timer(&hci_stack->timeout, 100);
run_loop_add_timer(&hci_stack->timeout);
}
@ -965,7 +965,7 @@ static void hci_initializing_run(void){
log_info("hci_run: init script done");
// Init script download causes baud rate to reset on Broadcom chipsets, restore UART baud rate if needed
if (hci_stack->manufacturer == 0x000f){
if (hci_stack->manufacturer == COMPANY_ID_BROADCOM_CORPORATION){
int need_baud_change = hci_stack->config
&& hci_stack->control
&& hci_stack->control->baudrate_cmd
@ -1136,7 +1136,7 @@ static void hci_initializing_event_handler(uint8_t * packet, uint16_t size){
case HCI_INIT_W4_SEND_BAUD_CHANGE:
// for STLC2500D, baud rate change already happened.
// for others, baud rate gets changed now
if (hci_stack->manufacturer != 0x0030){
if (hci_stack->manufacturer != COMPANY_ID_ST_MICROELECTRONICS){
uint32_t baud_rate = hci_transport_uart_get_main_baud_rate();
log_info("Local baud rate change to %"PRIu32, baud_rate);
hci_stack->hci_transport->set_baudrate(baud_rate);
@ -1152,7 +1152,7 @@ static void hci_initializing_event_handler(uint8_t * packet, uint16_t size){
hci_stack->substate = HCI_INIT_CUSTOM_INIT;
return;
case HCI_INIT_W4_READ_LOCAL_SUPPORTED_COMMANDS:
if (need_baud_change && hci_stack->manufacturer == 0x000f){
if (need_baud_change && hci_stack->manufacturer == COMPANY_ID_BROADCOM_CORPORATION){
hci_stack->substate = HCI_INIT_SEND_BAUD_CHANGE_BCM;
return;
}
@ -1175,7 +1175,7 @@ static void hci_initializing_event_handler(uint8_t * packet, uint16_t size){
}
case HCI_INIT_W4_SET_BD_ADDR:
// for STLC2500D, bd addr change only gets active after sending reset command
if (hci_stack->manufacturer == 0x0030){
if (hci_stack->manufacturer == COMPANY_ID_ST_MICROELECTRONICS){
hci_stack->substate = HCI_INIT_SEND_RESET_ST_WARM_BOOT;
return;
}