extract hci_transport_uart_get_main_baud_rate
This commit is contained in:
parent
7dd9d0ecf8
commit
96b53536ee
40
src/hci.c
40
src/hci.c
@ -840,6 +840,16 @@ void le_handle_advertisement_report(uint8_t *packet, int size){
|
||||
}
|
||||
#endif
|
||||
|
||||
static uint32_t hci_transport_uart_get_main_baud_rate(void){
|
||||
if (!hci_stack->config) return 0;
|
||||
uint32_t baud_rate = ((hci_uart_config_t *)hci_stack->config)->baudrate_main;
|
||||
// Limit baud rate for Broadcom chipsets to 3 mbps
|
||||
if (hci_stack->manufacturer == 0x000f && baud_rate > 3000000){
|
||||
baud_rate = 3000000;
|
||||
}
|
||||
return baud_rate;
|
||||
}
|
||||
|
||||
static void hci_initialization_timeout_handler(timer_source_t * ds){
|
||||
switch (hci_stack->substate){
|
||||
case HCI_INIT_W4_SEND_RESET:
|
||||
@ -855,11 +865,7 @@ static void hci_initialization_timeout_handler(timer_source_t * ds){
|
||||
hci_run();
|
||||
break;
|
||||
case HCI_INIT_W4_SEND_BAUD_CHANGE: {
|
||||
uint32_t baud_rate = ((hci_uart_config_t *)hci_stack->config)->baudrate_main;
|
||||
// Limit baud rate for Broadcom chipsets to 3 mbps
|
||||
if (hci_stack->manufacturer == 0x000f && baud_rate > 3000000){
|
||||
baud_rate = 3000000;
|
||||
}
|
||||
uint32_t baud_rate = hci_transport_uart_get_main_baud_rate();
|
||||
log_info("Local baud rate change to %"PRIu32, baud_rate);
|
||||
hci_stack->hci_transport->set_baudrate(baud_rate);
|
||||
break;
|
||||
@ -910,11 +916,7 @@ static void hci_initializing_run(void){
|
||||
hci_send_cmd(&hci_reset);
|
||||
break;
|
||||
case HCI_INIT_SEND_BAUD_CHANGE: {
|
||||
uint32_t baud_rate = ((hci_uart_config_t *)hci_stack->config)->baudrate_main;
|
||||
// Limit baud rate for Broadcom chipsets to 3 mbps
|
||||
if (hci_stack->manufacturer == 0x000f && baud_rate > 3000000){
|
||||
baud_rate = 3000000;
|
||||
}
|
||||
uint32_t baud_rate = hci_transport_uart_get_main_baud_rate();
|
||||
hci_stack->control->baudrate_cmd(hci_stack->config, baud_rate, hci_stack->hci_packet_buffer);
|
||||
hci_stack->last_cmd_opcode = READ_BT_16(hci_stack->hci_packet_buffer, 0);
|
||||
hci_stack->substate = HCI_INIT_W4_SEND_BAUD_CHANGE;
|
||||
@ -928,11 +930,7 @@ static void hci_initializing_run(void){
|
||||
break;
|
||||
}
|
||||
case HCI_INIT_SEND_BAUD_CHANGE_BCM: {
|
||||
uint32_t baud_rate = ((hci_uart_config_t *)hci_stack->config)->baudrate_main;
|
||||
// Limit baud rate for Broadcom chipsets to 3 mbps
|
||||
if (hci_stack->manufacturer == 0x000f && baud_rate > 3000000){
|
||||
baud_rate = 3000000;
|
||||
}
|
||||
uint32_t baud_rate = hci_transport_uart_get_main_baud_rate();
|
||||
hci_stack->control->baudrate_cmd(hci_stack->config, baud_rate, hci_stack->hci_packet_buffer);
|
||||
hci_stack->last_cmd_opcode = READ_BT_16(hci_stack->hci_packet_buffer, 0);
|
||||
hci_stack->substate = HCI_INIT_W4_SEND_BAUD_CHANGE_BCM;
|
||||
@ -1139,11 +1137,7 @@ static void hci_initializing_event_handler(uint8_t * packet, uint16_t size){
|
||||
// for STLC2500D, baud rate change already happened.
|
||||
// for others, baud rate gets changed now
|
||||
if (hci_stack->manufacturer != 0x0030){
|
||||
// Limit baud rate for Broadcom chipsets to 3 mbps
|
||||
uint32_t baud_rate = ((hci_uart_config_t *)hci_stack->config)->baudrate_main;
|
||||
if (hci_stack->manufacturer == 0x000f && baud_rate > 3000000){
|
||||
baud_rate = 3000000;
|
||||
}
|
||||
uint32_t baud_rate = hci_transport_uart_get_main_baud_rate();
|
||||
log_info("Local baud rate change to %"PRIu32, baud_rate);
|
||||
hci_stack->hci_transport->set_baudrate(baud_rate);
|
||||
}
|
||||
@ -1169,11 +1163,7 @@ static void hci_initializing_event_handler(uint8_t * packet, uint16_t size){
|
||||
hci_stack->substate = HCI_INIT_READ_BD_ADDR;
|
||||
return;
|
||||
case HCI_INIT_W4_SEND_BAUD_CHANGE_BCM: {
|
||||
// Limit baud rate for Broadcom chipsets to 3 mbps
|
||||
uint32_t baud_rate = ((hci_uart_config_t *)hci_stack->config)->baudrate_main;
|
||||
if (hci_stack->manufacturer == 0x000f && baud_rate > 3000000){
|
||||
baud_rate = 3000000;
|
||||
}
|
||||
uint32_t baud_rate = hci_transport_uart_get_main_baud_rate();
|
||||
log_info("Local baud rate change to %"PRIu32" after init script", baud_rate);
|
||||
hci_stack->hci_transport->set_baudrate(baud_rate);
|
||||
if (need_addr_change){
|
||||
|