hfp_ag: only send AG indicators if enabled with AT+CMER=3,0,0,1

This commit is contained in:
Matthias Ringwald 2022-03-16 10:25:07 +01:00
parent c814a90472
commit 69640b0415

View File

@ -2064,16 +2064,12 @@ static int hfp_ag_send_commands(hfp_connection_t *hfp_connection){
return 1;
}
// update AG indicators
if (hfp_connection->ag_indicators_status_update_bitmap){
int i;
// update AG indicators only if enabled by AT+CMER=3,0,0,1
if ((hfp_connection->enable_status_update_for_ag_indicators == 1) && (hfp_connection->ag_indicators_status_update_bitmap != 0)){
uint16_t i;
for (i=0;i<hfp_connection->ag_indicators_nr;i++){
if (get_bit(hfp_connection->ag_indicators_status_update_bitmap, i)){
hfp_connection->ag_indicators_status_update_bitmap = store_bit(hfp_connection->ag_indicators_status_update_bitmap, i, 0);
if (!hfp_connection->enable_status_update_for_ag_indicators) {
log_info("+CMER:3,0,0,0 - not sending update for '%s'", hfp_ag_indicators[i].name);
break;
}
hfp_ag_send_transfer_ag_indicators_status_cmd(hfp_connection->rfcomm_cid, &hfp_ag_indicators[i]);
return 1;
}